Generatoare Valtra

Generatoarele Valtra oferă o opțiune fiabilă și rentabilă pentru alimentarea de la distanță și de rezervă. Ei folosesc întreaga gamă de motoare AGCO POWER testate și fabricate în Linnavuori, Finlanda.
Valtra are generatoare de energie pentru fiecare situație, cu șase modele, de la 60 kVA la 250 kVA.
| Model | VG60 | VG90 | VG110 | VG150 | VG200 | VG250 |
| Power Prime (PRP) kVA / kW | 60 / 48 | 90 / 72 | 110 / 88 | 150 / 120 | 205 / 164 | 250 / 200 |
| Power Standby (LTP) kVA / kW | 66 / 53 | 99 / 79 | 121 / 97 | 165 / 132 | 225 / 180 | 275 / 220 |
| Engine model (AGCO POWER) | 33 DTG | 49 DTG | 49 DTAG | 74 DTG | 74 DTAG | 84 WIG |
| Cylinder qty | 3 | 4 | 4 | 6 | 6 | 6 |
| Rev. speed, rpm | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 |
| Generator | ECP322M4B | ECP342S4A | ECP341L4A | ECP342L4A | ECO383S4A | ECO381L4A |
| Power factor, cos φ | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. | 0.8 ind. |
| Electric system voltage, V | 12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC | 12 VDC |
| Generator IP protection rating | IP23 | IP23 | IP23 | IP23 | IP23 | IP23 |
| Aggregate nominal voltage, V | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 | 400 / 230 |
| Combustion air, m³/min | 5 | 7,5 | 10 | 12,6 | 17 | 15,5 |
| Cooling air, m³/min | 110 | 145 | 174 | 216 | 234 | 300 |
| Opening f. d. cooling air m² | 0.36 | 0.48 | 0.55 | 0.64 | 0.8 | 1.0 |
| Aggregate nominal current, A (PRP) | 87 | 130 | 159 | 218 | 296 | 361 |
| Rated current of the electr. Systems A | 125 | 160 | 250 | 250 | 400 | 400 |
| Main Fuses, A | 100 | 160 | 250 | 250 | 400 | 630 |
| Short circuit current, A, 10 s | > 261 | > 390 | > 477 | > 654 | > 888 | > 1.083 |
| Fuel tank capacity (l) | 200 / 200 | 200 / 300 | 350 / 300 | 350 / 300 | 350 / 300 | 350 / 350 |
| Working hours with full tank at 100% power, (open / weather protected) | 13 / 13 | 08.05.2013 | 13.11.2005 | 10.08.2005 | 07.июн | 07.июл |
| Fuel consumption @ 100% PRP (l/h) | 14.июл | 23 | 26 | 34 | 48.5 | 49 |
| Noise level, weather protected, dB (Lp (7 m) / Lw) | 66 / 90.9 | 71.4 / 96.3 | 72.7 / 97.6 | 71.1 / 96 | 74.2 / 99.1 | 73.3 / 98.2 |
| Length, open / weather protected (mm) | 2180 / 2310 | 2250 / 2920 | 2650 / 2920 | 2750 / 2920 | 2850 / 2920 | 3220 / 4210 |
| Width, open / weather protected (mm) | 660 / 1120 | 660 / 1150 | 990 / 1150 | 850 / 1150 | 990 / 1150 | 1100 / 1365 |
| Height, open / weather protected (mm) | 1425 / 1950 | 1475 / 2170 | 1625 / 2170 | 1695 / 2170 | 1725 / 2170 | 1780 / 2150 |
| Dry weight, open / weather protected (kg) | 1000 / 1400 | 1300 / 1800 | 1400 / 1900 | 1600 / 2100 | 1700 / 2250 | 2600 / 3070 |